Description
Superior Features
It Incorporates High Incubation, Separation Capacity, Rapid Filtration, Etc
Vacuum Source: Electrical Vacuum suction pump for filtration with Help of Pressure Mode
Fixed filtration glass chamber in the filtration module
Sample loading :Individual sample loading with independent mechanical control
Control valves :Individual control valves for vacuum and filtration.
Uniquely designed expansion vessel to feed samples after enzymatic digestion & residue collection vessel
Counter pressure option with reverse air stream
Essential Accessories like Crucible Rubber, Extractor Rubber, Teflon Bush & Nylon Bush.
Bath designed for studies on Tissue metabolism, Enzymes and Protein coagulation & experiments requiring
Shaking of subject matter at constant speed under controlled temperature environment
System consists of stirring in SS water tank with reciprocal motion with thermostatic heating bath..
Enzymatic digestion vessel. Microprocessor based Digital PID Temperature controller with auto tuning facility
Temperature Range :Ambient to 110°C, Temperature accuracy: ±0.5°C, Repeatability<0.5%
Strokes:0-120 strokes/minute continuously variable, Filtration Flask Capacity:500-600 ml.
Drive :Heavy duty DC motor designed for uniform noiseless motion
Shaking speed can be controlled by means of Electronic Speed Controller cum Digital Indicator upto 150 RPM.
Speed Indication: Digital LED Display, Incubation flasks for digestion purpose (500-600 ml)
Heater: Immersion heater thermostatically controlled
Inner tank made of Stainless Steel-316 grade and Exterior of Stainless Steel-304 grade in GMP MODEL.
High density glass wool insulation to prevent heat loss & ensure constant temperature.
Shaking tray consist of Lotus clamps to hold Erlenmeyer flasks.
High grade Silica glass Crucible with P2 (P100) Disc ,40-100 μm Microns for free flow of reagent while operation
Timer should be inbuilt digital timer:0 to 99.59 Settable in Hrs. Mins & Sec.
Vacuum source –Dietary Fibre with self priming pump connected to water suction glass filter pump for rapid filtrations. Speed setting with Rotary potentiometric knob for continuously variable speed
Speed Indication should be Digital Display with LED indication
High grade Silica glass Crucible with P1 grade disc,40-90 μm Microns(70mm height) Optional (P0/P2) for free flow of reagent while operation
Safety Features
Over temperature protection, Auto error Indication, Sensor break protection.
Heater cut off feature with buzzer indication and alarm, Acoustic signals with
visual display Auto tuning facility, Anti vibration mount, Auto stop & Start feature
Reviews